Show Hamamatsu Avalanche Photo Diode 1410015837 - Archived data from Tue, 11. August 2020 17:25:38 CEST
This is all the information about APD 1410015837. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1410015837 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | F03 |
| Break-through voltage: | 426 V |
| Voltage for Gain 100 (T=+25°C): | 396.9 V |
| Dark current: | 5.3 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 37 |
| Position in Box: | 1 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 391 |
| Position in grid: | 0 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 03. Jan 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 05. Dec 2018 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 10. Dec 2018 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 397.3117993 V T = -25 °C: 360.7091894 V |
| Voltage for Gain 150: | T = +20 °C: 405.3546182 V T = -25 °C: 368.573391 V |
| Voltage for Gain 200: | T = +20 °C: 409.8064878 V T = -25 °C: 372.9195873 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.995723218 V-1 T = -25 °C: 4.62163798 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.714965514 V-1 T = -25 °C: 8.167676396 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 15.63045536 V-1 T = -25 °C: 14.7623471 V-1 |
| Break-through voltage: | T = +20 °C: 425.6350292 V T = -25 °C: 388.9329227 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 10:52:46 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:18:41 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:25:38 CEST | jreher | Updated APD characteristics via API. |
| 28. Nov 2019 12:23:10 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:13:47 CET | jreher | Updated box and position via API. |
| 13. Jun 2019 11:29:54 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:48:08 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:33:03 CEST | jreher | Updated APD batch assignment via API. |
| 03. Jan 2019 12:55:43 CET | markus.moritz | |
| 29. Sep 2017 12:25:44 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:25 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:39:41 CEST | Tobias | Imported from Hamamatsu datasheet. |