Show Hamamatsu Avalanche Photo Diode 1408015697 - Archived data from Tue, 11. August 2020 17:25:49 CEST
This is all the information about APD 1408015697. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1408015697 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | A06 |
| Break-through voltage: | 418 V |
| Voltage for Gain 100 (T=+25°C): | 391.1 V |
| Dark current: | 8.7 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 38 |
| Position in Box: | 3 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 384 |
| Position in grid: | 19 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 16. Jan 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 28. Nov 2018 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 30. Nov 2018 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 390.4608088 V T = -25 °C: 354.1858384 V |
| Voltage for Gain 150: | T = +20 °C: 398.4817972 V T = -25 °C: 361.7921345 V |
| Voltage for Gain 200: | T = +20 °C: 402.9038856 V T = -25 °C: 366.1026391 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.526592476 V-1 T = -25 °C: 4.973474035 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.21336546 V-1 T = -25 °C: 9.094777186 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 13.59816317 V-1 T = -25 °C: 14.37432698 V-1 |
| Break-through voltage: | T = +20 °C: 416.9806361 V T = -25 °C: 380.6748544 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 10:53:04 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:18:49 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:25:49 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:35:41 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:13:52 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:10:45 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:48:13 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:33:09 CEST | jreher | Updated APD batch assignment via API. |
| 18. Jan 2019 14:46:39 CET | markus.moritz | |
| 03. Dec 2018 13:20:34 CET | markus.moritz | |
| 29. Sep 2017 14:07:20 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:21 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:32:29 CEST | Tobias | Imported from Hamamatsu datasheet. |