Subdetector specification:  
Serial: 1408015638
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G12
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 393.5 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 36
Position in Box: 34
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 382
Position in grid: 0
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 05. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 394.0376991 V     T = -25 °C: 357.5252377 V
Voltage for Gain 150: T = +20 °C: 401.935942 V     T = -25 °C: 365.2201942 V
Voltage for Gain 200: T = +20 °C: 406.3173882 V     T = -25 °C: 369.5778195 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.308442733 V-1     T = -25 °C: 4.863088394 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.384207435 V-1     T = -25 °C: 8.567621063 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.48271211 V-1     T = -25 °C: 13.76466904 V-1
Break-through voltage: T = +20 °C: 419.2273646 V     T = -25 °C: 385.4121997 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 13:16:51 CET oafedulidis Assigned to capsule by script
16. Dec 2021 13:41:16 CET oafedulidis Updated box and position via API.
05. Feb 2021 10:52:42 CET jreher Updated box and position via API.
03. Feb 2021 18:18:37 CET jreher Updated box and position via API.
11. Aug 2020 17:25:35 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:23:01 CET jreher Updated APD location via API.
25. Nov 2019 17:13:44 CET jreher Updated box and position via API.
13. Jun 2019 11:29:43 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:07 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:02 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 12:35:21 CET markus.moritz
29. Sep 2017 12:25:25 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:19 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:27 CEST Tobias Imported from Hamamatsu datasheet.