Show Hamamatsu Avalanche Photo Diode 1406015528 - Archived data from Tue, 11. August 2020 17:26:21 CEST
This is all the information about APD 1406015528. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1406015528 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F05 |
Break-through voltage: | 418 V |
Voltage for Gain 100 (T=+25°C): | 389.7 V |
Dark current: | 5.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 41 |
Position in Box: | 16 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 376 |
Position in grid: | 18 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 26. Nov 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 22. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 23. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 389.8749609 V T = -25 °C: 353.6851121 V |
Voltage for Gain 150: | T = +20 °C: 397.8493815 V T = -25 °C: 361.284637 V |
Voltage for Gain 200: | T = +20 °C: 402.2453833 V T = -25 °C: 365.5700459 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.521088106 V-1 T = -25 °C: 4.943585401 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.210878604 V-1 T = -25 °C: 8.862472573 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.11852838 V-1 T = -25 °C: 15.18934719 V-1 |
Break-through voltage: | T = +20 °C: 418.277376 V T = -25 °C: 381.6689089 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:53:29 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:15 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:26:21 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:36:15 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:09 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:10 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:28 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:24 CEST | jreher | Updated APD batch assignment via API. |
26. Nov 2018 14:27:14 CET | markus.moritz | |
29. Sep 2017 13:35:59 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:16 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:32:24 CEST | Tobias | Imported from Hamamatsu datasheet. |