RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1406015514 - Archived data from Wed, 03. February 2021 18:19:24 CET


This is all the information about APD 1406015514. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1406015514
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 420 V
Voltage for Gain 100 (T=+25°C): 392.3 V
Dark current: 5.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 42
Position in Box: 14
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 376
Position in grid: 5
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.0127528 V     T = -25 °C: 355.6332661 V
Voltage for Gain 150: T = +20 °C: 399.9784371 V     T = -25 °C: 363.2950859 V
Voltage for Gain 200: T = +20 °C: 404.4037942 V     T = -25 °C: 367.6276905 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.404326244 V-1     T = -25 °C: 4.75134299 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.191038063 V-1     T = -25 °C: 9.185889324 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.94632195 V-1     T = -25 °C: 15.55870333 V-1
Break-through voltage: T = +20 °C: 419.218423 V     T = -25 °C: 382.8016967 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:53:36 CET jreher Updated box and position via API.
03. Feb 2021 18:19:24 CET jreher Updated box and position via API.
11. Aug 2020 17:26:30 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:36:26 CET jreher Updated APD location via API.
25. Nov 2019 17:14:15 CET jreher Updated box and position via API.
04. Jul 2019 11:11:18 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:32 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:28 CEST jreher Updated APD batch assignment via API.
26. Nov 2018 14:36:22 CET markus.moritz
29. Sep 2017 13:35:59 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:15 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:24 CEST Tobias Imported from Hamamatsu datasheet.