RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1406015497 - Archived data from Tue, 11. August 2020 17:25:33 CEST


This is all the information about APD 1406015497. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1406015497
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G11
Break-through voltage: 422 V
Voltage for Gain 100 (T=+25°C): 393.2 V
Dark current: 5.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 36
Position in Box: 25
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 375
Position in grid: 8
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 05. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.6823386 V     T = -25 °C: 357.6721167 V
Voltage for Gain 150: T = +20 °C: 401.6719237 V     T = -25 °C: 365.4527908 V
Voltage for Gain 200: T = +20 °C: 406.0963167 V     T = -25 °C: 369.876241 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.628666651 V-1     T = -25 °C: 4.656932661 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.341674355 V-1     T = -25 °C: 8.464195952 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.20273272 V-1     T = -25 °C: 15.79929022 V-1
Break-through voltage: T = +20 °C: 421.6237872 V     T = -25 °C: 384.9570121 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:52:41 CET jreher Updated box and position via API.
03. Feb 2021 18:18:36 CET jreher Updated box and position via API.
11. Aug 2020 17:25:33 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:23:00 CET jreher Updated APD location via API.
25. Nov 2019 17:13:44 CET jreher Updated box and position via API.
13. Jun 2019 11:29:43 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:06 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:01 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 12:13:00 CET markus.moritz
29. Sep 2017 11:17:36 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:15 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:23 CEST Tobias Imported from Hamamatsu datasheet.