Show Hamamatsu Avalanche Photo Diode 1405015447 - Archived data from Tue, 11. August 2020 17:26:26 CEST
					This is all the information about APD 1405015447. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1405015447 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | Bochum | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | E10 | 
| Break-through voltage: | 418 V | 
| Voltage for Gain 100 (T=+25°C): | 389.7 V | 
| Dark current: | 4.8 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 41 | 
| Position in Box: | 43 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | 373 | 
| Position in grid: | 2 | 
| Arrival for irradiation: | 29. Sep 2017 | 
| Sent for analysis after irradiation: | 26. Nov 2018 | 
| Return for assembly: | none | 
| Irradiation: | |
| Date: | 22. Nov 2018 | 
| Dose used: | 37 Gy | 
| Temperature: | 20 °C | 
| Position: | none | 
| Bias voltage: | none | 
| Annealing: | |
| Date: | 23. Nov 2018 | 
| Temperature: | 80 °C | 
| Duration: | 48 h | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 390.2790586 V T = -25 °C: 353.915828 V | 
| Voltage for Gain 150: | T = +20 °C: 398.2491886 V T = -25 °C: 361.5285052 V | 
| Voltage for Gain 200: | T = +20 °C: 402.6876723 V T = -25 °C: 365.818305 V | 
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.32265767 V-1 T = -25 °C: 4.687312853 V-1 | 
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.001111665 V-1 T = -25 °C: 9.08698891 V-1 | 
| Gain/Voltage slope at M = 200: | T = +20 °C: 15.26578421 V-1 T = -25 °C: 15.51609581 V-1 | 
| Break-through voltage: | T = +20 °C: 417.7399915 V T = -25 °C: 380.9809814 V | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 05. Feb 2021 10:53:32 CET | jreher | Updated box and position via API. | 
| 03. Feb 2021 18:19:19 CET | jreher | Updated box and position via API. | 
| 11. Aug 2020 17:26:26 CEST | jreher | Updated APD characteristics via API. | 
| 27. Nov 2019 19:36:17 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:14:12 CET | jreher | Updated box and position via API. | 
| 04. Jul 2019 11:11:12 CEST | jreher | Updated APD location via API. | 
| 12. Jun 2019 16:48:30 CEST | jreher | Updated APD batch assignment via API. | 
| 12. Jun 2019 16:33:27 CEST | jreher | Updated APD batch assignment via API. | 
| 26. Nov 2018 15:25:08 CET | markus.moritz | |
| 29. Sep 2017 13:35:32 CEST | markus.moritz | Entered arrival for irradiation date. | 
| 01. Aug 2016 17:29:14 CEST | Tobias | Assigned to grid via information extracted from APD DB. | 
| 23. Jun 2016 10:32:22 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					