Show Hamamatsu Avalanche Photo Diode 1403015265 - Archived data from Fri, 27. August 2021 10:30:07 CEST
This is all the information about APD 1403015265. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1403015265 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | E03 |
| Break-through voltage: | 414 V |
| Voltage for Gain 100 (T=+25°C): | 386.2 V |
| Dark current: | 9.9 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 307 |
| Position in Box: | 32 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 364 |
| Position in grid: | 10 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 27. Oct 2017 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 25. Oct 2017 |
| Dose used: | 45 Gy |
| Temperature: | 20 °C |
| Position: | 3 |
| Bias voltage: | 386.2 V (connected) |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 387.1319425 V T = -25 °C: 351.4141352 V |
| Voltage for Gain 150: | T = +20 °C: 395.0491226 V T = -25 °C: 358.9093512 V |
| Voltage for Gain 200: | T = +20 °C: 399.4527406 V T = -25 °C: 363.131315 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.519825309 V-1 T = -25 °C: 4.686884226 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.855792113 V-1 T = -25 °C: 9.377176225 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 15.46394786 V-1 T = -25 °C: 14.66183836 V-1 |
| Break-through voltage: | T = +20 °C: 413.9614543 V T = -25 °C: 377.6626259 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 16. Nov 2021 10:24:18 CET | oafedulidis | Assigned to capsule by script |
| 27. Aug 2021 10:30:07 CEST | oafedulidis | Updated box and position via API. |
| 05. Feb 2021 11:28:05 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:58:23 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:44:41 CEST | jreher | Updated APD location via API. |
| 21. Jul 2020 14:44:31 CEST | jreher | Updated box and position via API. |
| 19. Dec 2019 16:35:44 CET | spankonin | Updated APD batch assignment via API. |
| 19. Dec 2019 15:18:46 CET | jreher | Updated box and position via API. |
| 27. Oct 2017 10:38:08 CEST | markus.moritz | Entered shipped after irradiation date. |
| 26. Oct 2017 16:27:44 CEST | markus.moritz | Entered irradiation information. |
| 29. Sep 2017 12:17:00 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:07 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:31:19 CEST | Tobias | Imported from Hamamatsu datasheet. |