RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1402015205 - Archived data from Mon, 25. November 2019 17:31:38 CET


This is all the information about APD 1402015205. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1402015205
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum Box 292
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D04
Break-through voltage: 424 V
Voltage for Gain 100 (T=+25°C): 395.6 V
Dark current: 6.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 292
Position in Box: 33
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 361
Position in grid: 15
Arrival for irradiation: 19. Sep 2016
Sent for analysis after irradiation: 30. Sep 2016
Return for assembly: 02. Nov 2016
   
Irradiation:  
Date: 28. Sep 2016
Dose used: 36 Gy
Temperature: 20 °C
Position: 1
Bias voltage: 350 V     (connected)
   
Annealing:  
Date: 28. Sep 2016
Temperature: 80 °C
Duration: 10 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:26:00 CET jreher Updated box and position via API.
07. Oct 2020 15:44:59 CEST jreher Updated APD location via API.
11. Aug 2020 17:40:43 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:41:02 CEST jreher Updated box and position via API.
27. Nov 2019 20:19:13 CET jreher Updated APD location via API.
25. Nov 2019 17:31:38 CET jreher Updated box and position via API.
22. Oct 2019 14:33:21 CEST spankonin Updated APD location via API.
15. Oct 2019 11:00:19 CEST jgrochowski Updated APD batch assignment via API.
02. Nov 2016 14:38:08 CET markus.moritz Entered return for assembly date.
07. Oct 2016 10:47:09 CEST christopher.l.hahn Entered irradiation information.
05. Oct 2016 15:43:08 CEST markus.moritz Entered shipped after irradiation date.
28. Sep 2016 14:01:21 CEST christopher.l.hahn Entered annealing information.
28. Sep 2016 14:00:19 CEST christopher.l.hahn Entered irradiation information.
28. Sep 2016 13:59:25 CEST christopher.l.hahn Entered irradiation information.
23. Sep 2016 09:11:06 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:05 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:31:17 CEST Tobias Imported from Hamamatsu datasheet.