RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1402015182 - Archived data from Tue, 11. August 2020 17:26:33 CEST


This is all the information about APD 1402015182. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1402015182
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E08
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 392.2 V
Dark current: 5.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 42
Position in Box: 32
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 360
Position in grid: 12
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.5103882 V     T = -25 °C: 355.7479642 V
Voltage for Gain 150: T = +20 °C: 400.5148633 V     T = -25 °C: 363.3839397 V
Voltage for Gain 200: T = +20 °C: 404.9406497 V     T = -25 °C: 367.7065331 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.260815721 V-1     T = -25 °C: 4.965442268 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.418165604 V-1     T = -25 °C: 8.74457941 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.23026729 V-1     T = -25 °C: 14.3465168 V-1
Break-through voltage: T = +20 °C: 420.5475159 V     T = -25 °C: 383.4117626 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:53:39 CET jreher Updated box and position via API.
03. Feb 2021 18:19:26 CET jreher Updated box and position via API.
11. Aug 2020 17:26:33 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:36:27 CET jreher Updated APD location via API.
25. Nov 2019 17:14:16 CET jreher Updated box and position via API.
04. Jul 2019 11:11:20 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:33 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:30 CEST jreher Updated APD batch assignment via API.
26. Nov 2018 14:21:13 CET markus.moritz
29. Sep 2017 12:34:10 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:05 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:31:17 CEST Tobias Imported from Hamamatsu datasheet.