RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1401015109 - Archived data from Wed, 03. February 2021 18:17:38 CET


This is all the information about APD 1401015109. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1401015109
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E09
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 392.5 V
Dark current: 5.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 29
Position in Box: 4
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 357
Position in grid: 3
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 16. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 30. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.1474319 V     T = -25 °C: 356.5205268 V
Voltage for Gain 150: T = +20 °C: 401.137482 V     T = -25 °C: 364.1996861 V
Voltage for Gain 200: T = +20 °C: 405.5816573 V     T = -25 °C: 368.5413325 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.337421121 V-1     T = -25 °C: 4.736198345 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.027324667 V-1     T = -25 °C: 9.229912767 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.3002374 V-1     T = -25 °C: 13.9486237 V-1
Break-through voltage: T = +20 °C: 421.2762342 V     T = -25 °C: 384.2930284 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:28:45 CEST oafedulidis Assigned to capsule by script
30. Aug 2021 14:08:13 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:51:32 CET jreher Updated box and position via API.
03. Feb 2021 18:17:38 CET jreher Updated box and position via API.
11. Aug 2020 17:24:20 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:34:37 CET jreher Updated APD location via API.
25. Nov 2019 17:13:08 CET jreher Updated box and position via API.
04. Jul 2019 11:10:08 CEST jreher Updated APD location via API.
17. Jun 2019 11:27:39 CEST jreher Updated APD location via API.
13. Jun 2019 11:28:11 CEST jreher Updated APD location via API.
13. Jun 2019 11:07:29 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:32 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:27 CEST jreher Updated APD batch assignment via API.
18. Jan 2019 14:26:11 CET markus.moritz
03. Dec 2018 11:24:36 CET markus.moritz
29. Sep 2017 09:56:10 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:02 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:31:15 CEST Tobias Imported from Hamamatsu datasheet.