Show Hamamatsu Avalanche Photo Diode 1320015007 - Archived data from Tue, 11. August 2020 18:04:00 CEST
This is all the information about APD 1320015007. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1320015007 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A07 |
Break-through voltage: | 446 V |
Voltage for Gain 100 (T=+25°C): | 418.8 V |
Dark current: | 9.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 285 |
Position in Box: | 11 |
EP1 batch: | 203 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 352 |
Position in grid: | 17 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 418.7342113 V T = -25 °C: 382.1195008 V |
Voltage for Gain 150: | T = +20 °C: 426.7614794 V T = -25 °C: 390.0269752 V |
Voltage for Gain 200: | T = +20 °C: 431.2260156 V T = -25 °C: 394.4288658 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.572781547 V-1 T = -25 °C: 4.507802514 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.933411471 V-1 T = -25 °C: 8.812897867 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.80079222 V-1 T = -25 °C: 15.43236039 V-1 |
Break-through voltage: | T = +20 °C: 439.9239316 V T = -25 °C: 409.8900153 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:04 CET | jreher | Updated box and position via API. |
11. Aug 2020 18:04:00 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:39:51 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:39:42 CEST | jreher | Updated box and position via API. |
10. Feb 2020 18:57:51 CET | spankonin | Updated APD batch assignment via API. |
29. Nov 2019 11:50:14 CET | jreher | Updated APD location via API. |
27. Nov 2019 20:17:58 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:04 CET | jreher | Updated box and position via API. |
22. Oct 2019 13:10:53 CEST | spankonin | Updated APD location via API. |
09. Oct 2019 11:44:02 CEST | jgrochowski | Updated APD batch assignment via API. |
29. Sep 2017 09:56:52 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:59 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:29:51 CEST | Tobias | Imported from Hamamatsu datasheet. |