RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1319014983 - Archived data from Thu, 08. September 2016 13:36:10 CEST


This is all the information about APD 1319014983. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1319014983
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: unknown
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F10
Break-through voltage: 438 V
Voltage for Gain 100 (T=+25°C): 409.9 V
Dark current: 7.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 292
Position in Box: 32
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 351
Position in grid: 14
Arrival for irradiation: 11. Aug 2016
Sent for analysis after irradiation: 02. Sep 2016
Return for assembly: none
   
Irradiation:  
Date: 23. Aug 2016
Dose used: 30 Gy
Temperature: 25 °C
Position: 2
Bias voltage: 350 V     (connection unknown)
   
Annealing:  
Date: 24. Aug 2016
Temperature: 80 °C
Duration: 10 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:26:00 CET jreher Updated box and position via API.
07. Oct 2020 15:44:59 CEST jreher Updated APD location via API.
11. Aug 2020 17:40:43 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:41:02 CEST jreher Updated box and position via API.
27. Nov 2019 20:19:13 CET jreher Updated APD location via API.
25. Nov 2019 17:31:38 CET jreher Updated box and position via API.
22. Oct 2019 14:33:21 CEST spankonin Updated APD location via API.
15. Oct 2019 11:00:19 CEST jgrochowski Updated APD batch assignment via API.
06. Oct 2016 09:45:00 CEST markus.moritz Entered return for assembly date.
08. Sep 2016 13:36:10 CEST markus.moritz Entered shipped after irradiation date.
24. Aug 2016 14:36:41 CEST christopher.l.hahn Entered irradiation information.
24. Aug 2016 14:24:26 CEST christopher.l.hahn Entered annealing information.
11. Aug 2016 11:48:04 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:58 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:29:50 CEST Tobias Imported from Hamamatsu datasheet.