Show Hamamatsu Avalanche Photo Diode 1319014974 - Archived data from Thu, 06. October 2016 09:45:00 CEST
					This is all the information about APD 1319014974. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1319014974 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | unknown | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | F07 | 
| Break-through voltage: | 435 V | 
| Voltage for Gain 100 (T=+25°C): | 406.2 V | 
| Dark current: | 6 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 292 | 
| Position in Box: | 31 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | 351 | 
| Position in grid: | 6 | 
| Arrival for irradiation: | 11. Aug 2016 | 
| Sent for analysis after irradiation: | 02. Sep 2016 | 
| Return for assembly: | 06. Oct 2016 | 
| Irradiation: | |
| Date: | 23. Aug 2016 | 
| Dose used: | 30 Gy | 
| Temperature: | 25 °C | 
| Position: | 2 | 
| Bias voltage: | 350 V (connected) | 
| Annealing: | |
| Date: | 24. Aug 2016 | 
| Temperature: | 80 °C | 
| Duration: | 10 h | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none | 
| Break-through voltage: | T = +20 °C: none T = -25 °C: none | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 05. Feb 2021 11:25:59 CET | jreher | Updated box and position via API. | 
| 07. Oct 2020 15:44:59 CEST | jreher | Updated APD location via API. | 
| 11. Aug 2020 17:40:43 CEST | jreher | Updated APD characteristics via API. | 
| 21. Jul 2020 14:41:02 CEST | jreher | Updated box and position via API. | 
| 27. Nov 2019 20:19:12 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:31:38 CET | jreher | Updated box and position via API. | 
| 22. Oct 2019 14:33:21 CEST | spankonin | Updated APD location via API. | 
| 15. Oct 2019 11:00:19 CEST | jgrochowski | Updated APD batch assignment via API. | 
| 06. Oct 2016 09:45:00 CEST | markus.moritz | Entered return for assembly date. | 
| 08. Sep 2016 13:36:10 CEST | markus.moritz | Entered shipped after irradiation date. | 
| 24. Aug 2016 14:36:40 CEST | christopher.l.hahn | Entered irradiation information. | 
| 24. Aug 2016 14:24:26 CEST | christopher.l.hahn | Entered annealing information. | 
| 11. Aug 2016 11:48:04 CEST | markus.moritz | Entered arrival for irradiation date. | 
| 01. Aug 2016 17:28:58 CEST | Tobias | Assigned to grid via information extracted from APD DB. | 
| 23. Jun 2016 10:29:50 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					