Show Hamamatsu Avalanche Photo Diode 1315014661 - Archived data from Wed, 07. October 2020 15:45:55 CEST
This is all the information about APD 1315014661. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1315014661 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | In transit to Mainz |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | B11 |
| Break-through voltage: | 444 V |
| Voltage for Gain 100 (T=+25°C): | 416 V |
| Dark current: | 10.9 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 35 |
| Position in Box: | 16 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 338 |
| Position in grid: | 3 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 03. Jan 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 05. Dec 2018 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 10. Dec 2018 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 416.5230722 V T = -25 °C: 379.9611675 V |
| Voltage for Gain 150: | T = +20 °C: 424.4949786 V T = -25 °C: 387.8286852 V |
| Voltage for Gain 200: | T = +20 °C: 428.9075289 V T = -25 °C: 392.1977031 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.634662767 V-1 T = -25 °C: 4.35031755 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.865937802 V-1 T = -25 °C: 9.219278151 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.59218851 V-1 T = -25 °C: 15.03358629 V-1 |
| Break-through voltage: | T = +20 °C: 439.918316 V T = -25 °C: 407.3611402 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 10:52:25 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:18:27 CET | jreher | Updated box and position via API. |
| 07. Oct 2020 15:45:55 CEST | jreher | Updated APD location via API. |
| 11. Aug 2020 17:25:21 CEST | jreher | Updated APD characteristics via API. |
| 28. Nov 2019 12:22:48 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:13:38 CET | jreher | Updated box and position via API. |
| 13. Jun 2019 11:29:28 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:48:00 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:32:56 CEST | jreher | Updated APD batch assignment via API. |
| 03. Jan 2019 13:18:45 CET | markus.moritz | |
| 29. Sep 2017 10:21:51 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:28:49 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:29:43 CEST | Tobias | Imported from Hamamatsu datasheet. |