RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1315014656 - Archived data from Tue, 11. August 2020 17:25:21 CEST


This is all the information about APD 1315014656. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1315014656
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D06
Break-through voltage: 436 V
Voltage for Gain 100 (T=+25°C): 407.1 V
Dark current: 11.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 35
Position in Box: 14
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 338
Position in grid: 1
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 05. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 407.7839301 V     T = -25 °C: 370.7217795 V
Voltage for Gain 150: T = +20 °C: 415.7778835 V     T = -25 °C: 378.6307535 V
Voltage for Gain 200: T = +20 °C: 420.2352725 V     T = -25 °C: 383.0563519 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.571047805 V-1     T = -25 °C: 4.518589022 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.033187254 V-1     T = -25 °C: 8.645577141 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.70938573 V-1     T = -25 °C: 13.72147915 V-1
Break-through voltage: T = +20 °C: 435.1364765 V     T = -25 °C: 398.0556832 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:52:24 CET jreher Updated box and position via API.
03. Feb 2021 18:18:27 CET jreher Updated box and position via API.
07. Oct 2020 15:45:55 CEST jreher Updated APD location via API.
11. Aug 2020 17:25:21 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:22:48 CET jreher Updated APD location via API.
25. Nov 2019 17:13:37 CET jreher Updated box and position via API.
13. Jun 2019 11:29:28 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:00 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:56 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 13:18:17 CET markus.moritz
29. Sep 2017 10:21:51 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:49 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:29:43 CEST Tobias Imported from Hamamatsu datasheet.