Show Hamamatsu Avalanche Photo Diode 1315014616 - Archived data from Tue, 11. August 2020 17:39:59 CEST
This is all the information about APD 1315014616. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1315014616 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | H07 |
| Break-through voltage: | 438 V |
| Voltage for Gain 100 (T=+25°C): | 409.3 V |
| Dark current: | 5.9 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 288 |
| Position in Box: | 10 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 336 |
| Position in grid: | 1 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 22. Feb 2018 |
| Dose used: | 30 Gy |
| Temperature: | 25 °C |
| Position: | 4 |
| Bias voltage: | 0 V (connected) |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 409.8398642 V T = -25 °C: 373.0928925 V |
| Voltage for Gain 150: | T = +20 °C: 417.7830534 V T = -25 °C: 380.9667921 V |
| Voltage for Gain 200: | T = +20 °C: 422.1939245 V T = -25 °C: 385.3447779 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.597295551 V-1 T = -25 °C: 4.54880058 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.044376819 V-1 T = -25 °C: 8.997061056 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.05117858 V-1 T = -25 °C: 13.92020861 V-1 |
| Break-through voltage: | T = +20 °C: 434.1464733 V T = -25 °C: 400.7061107 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:25:26 CET | jreher | Updated box and position via API. |
| 07. Oct 2020 15:44:43 CEST | jreher | Updated APD location via API. |
| 11. Aug 2020 17:39:59 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:40:19 CEST | jreher | Updated box and position via API. |
| 27. Nov 2019 20:18:27 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:31:18 CET | jreher | Updated box and position via API. |
| 22. Oct 2019 14:30:37 CEST | spankonin | Updated APD location via API. |
| 09. Oct 2019 11:26:59 CEST | jgrochowski | Updated APD batch assignment via API. |
| 05. Apr 2018 12:29:13 CEST | markus.moritz | Entered irradiation information. |
| 29. Sep 2017 12:05:25 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:28:49 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:29:42 CEST | Tobias | Imported from Hamamatsu datasheet. |