Show Hamamatsu Avalanche Photo Diode 0915010085 - Archived data from Wed, 27. November 2019 19:36:50 CET
					This is all the information about APD 0915010085. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 0915010085 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | Bochum | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | E10 | 
| Break-through voltage: | 406 V | 
| Voltage for Gain 100 (T=+25°C): | 377.1 V | 
| Dark current: | 4.8 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 44 | 
| Position in Box: | 43 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | 223 | 
| Position in grid: | 6 | 
| Arrival for irradiation: | 01. Jul 2016 | 
| Sent for analysis after irradiation: | 08. Jul 2016 | 
| Return for assembly: | 12. Sep 2016 | 
| Irradiation: | |
| Date: | 05. Jul 2016 | 
| Dose used: | 30 Gy | 
| Temperature: | 25 °C | 
| Position: | 4 | 
| Bias voltage: | 320 V (connection unknown) | 
| Annealing: | |
| Date: | 05. Jul 2016 | 
| Temperature: | 80 °C | 
| Duration: | 8 h | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none | 
| Break-through voltage: | T = +20 °C: none T = -25 °C: none | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 22. Feb 2021 11:10:51 CET | jreher | Updated box and position via API. | 
| 05. Feb 2021 10:53:53 CET | jreher | Updated box and position via API. | 
| 03. Feb 2021 18:19:41 CET | jreher | Updated box and position via API. | 
| 08. Dec 2020 17:17:17 CET | jreher | Assigned to capsule by script | 
| 06. Oct 2020 16:52:01 CEST | jreher | Updated box and position via API. | 
| 11. Aug 2020 17:26:55 CEST | jreher | Updated APD characteristics via API. | 
| 04. Aug 2020 15:48:20 CEST | jreher | Updated box and position via API. | 
| 27. Nov 2019 19:36:50 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:14:26 CET | jreher | Updated box and position via API. | 
| 04. Jul 2019 11:11:37 CEST | jreher | Updated APD location via API. | 
| 13. Jun 2019 10:01:30 CEST | jreher | Updated APD batch assignment via API. | 
| 12. Sep 2016 09:51:55 CEST | markus.moritz | Entered return for assembly date. | 
| 03. Aug 2016 16:41:04 CEST | markus.moritz | Entered irradiation information. | 
| 03. Aug 2016 16:15:32 CEST | markus.moritz | Entered shipped after irradiation date. | 
| 03. Aug 2016 16:15:21 CEST | markus.moritz | Entered arrival for irradiation date. | 
| 02. Aug 2016 14:56:29 CEST | christopher.l.hahn | Entered annealing information. | 
| 01. Aug 2016 17:27:33 CEST | Tobias | Assigned to grid via information extracted from APD DB. | 
| 23. Jun 2016 10:26:44 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					