RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1314014576 - Archived data from Tue, 11. August 2020 18:09:22 CEST


This is all the information about APD 1314014576. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1314014576
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B13
Break-through voltage: 452 V
Voltage for Gain 100 (T=+25°C): 423.9 V
Dark current: 9.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 326
Position in Box: 24
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 334
Position in grid: 3
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 413.4109985 V     T = -25 °C: 387.49758 V
Voltage for Gain 150: T = +20 °C: 423.7646516 V     T = -25 °C: 395.3354916 V
Voltage for Gain 200: T = +20 °C: 429.6590159 V     T = -25 °C: 399.0965547 V
Gain/Voltage slope at M = 100: T = +20 °C: 3.457589844 V-1     T = -25 °C: 4.432452883 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 6.870383988 V-1     T = -25 °C: 8.72244643 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 11.20655782 V-1     T = -25 °C: 26.33293491 V-1
Break-through voltage: T = +20 °C: 439.9904398 V     T = -25 °C: 414.9869262 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:21 CET jreher Updated APD characteristics via API.
10. Nov 2021 14:35:20 CET oafedulidis Updated APD location via API.
10. Nov 2021 14:35:05 CET oafedulidis Updated APD batch assignment via API.
05. Feb 2021 11:30:10 CET jreher Updated box and position via API.
07. Oct 2020 15:45:17 CEST jreher Updated APD location via API.
11. Aug 2020 18:09:22 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:46:06 CEST jreher Updated APD location via API.
21. Jul 2020 14:45:56 CEST jreher Updated box and position via API.
09. Jul 2020 15:02:39 CEST jreher Updated APD batch assignment via API.
27. Oct 2017 10:23:25 CEST Tobias Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated.
29. Sep 2017 09:53:30 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:47 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:42:37 CEST Tobias Imported from Hamamatsu datasheet.