RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1314014548 - Archived data from Wed, 07. October 2020 15:44:39 CEST


This is all the information about APD 1314014548. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1314014548
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E06
Break-through voltage: 442 V
Voltage for Gain 100 (T=+25°C): 413.3 V
Dark current: 9.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 284
Position in Box: 20
EP1 batch: 202
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 332
Position in grid: 19
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 413.3385284 V     T = -25 °C: 376.2335776 V
Voltage for Gain 150: T = +20 °C: 421.3659728 V     T = -25 °C: 384.1514483 V
Voltage for Gain 200: T = +20 °C: 425.8071611 V     T = -25 °C: 388.5499379 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.407726486 V-1     T = -25 °C: 4.499966296 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.573234815 V-1     T = -25 °C: 8.869057827 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.9065099 V-1     T = -25 °C: 13.80380618 V-1
Break-through voltage: T = +20 °C: 439.8911247 V     T = -25 °C: 404.5264345 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:58 CET jreher Updated box and position via API.
07. Oct 2020 15:44:39 CEST jreher Updated APD location via API.
11. Aug 2020 18:03:52 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:38 CEST jreher Updated APD location via API.
21. Jul 2020 14:39:28 CEST jreher Updated box and position via API.
10. Feb 2020 18:58:26 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:11 CET jreher Updated APD location via API.
27. Nov 2019 20:17:47 CET jreher Updated APD location via API.
25. Nov 2019 17:31:00 CET jreher Updated box and position via API.
22. Oct 2019 13:09:59 CEST spankonin Updated APD location via API.
09. Oct 2019 11:41:27 CEST jgrochowski Updated APD batch assignment via API.
29. Sep 2017 11:16:01 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:46 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:42:37 CEST Tobias Imported from Hamamatsu datasheet.