RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1313014521 - Archived data from Wed, 07. October 2020 15:44:54 CEST


This is all the information about APD 1313014521. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1313014521
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D05
Break-through voltage: 441 V
Voltage for Gain 100 (T=+25°C): 412.2 V
Dark current: 7.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 291
Position in Box: 38
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 331
Position in grid: 17
Arrival for irradiation: 11. Aug 2016
Sent for analysis after irradiation: 02. Sep 2016
Return for assembly: 06. Oct 2016
   
Irradiation:  
Date: 23. Aug 2016
Dose used: 30 Gy
Temperature: 25 °C
Position: 2
Bias voltage: 350 V     (connected)
   
Annealing:  
Date: 24. Aug 2016
Temperature: 80 °C
Duration: 10 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 412.6502165 V     T = -25 °C: 375.5749006 V
Voltage for Gain 150: T = +20 °C: 420.6678662 V     T = -25 °C: 383.5124639 V
Voltage for Gain 200: T = +20 °C: 425.101586 V     T = -25 °C: 387.9022801 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.300787814 V-1     T = -25 °C: 4.354563049 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.101407309 V-1     T = -25 °C: 8.443665781 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.07588997 V-1     T = -25 °C: 14.55610043 V-1
Break-through voltage: T = +20 °C: 439.9416688 V     T = -25 °C: 403.6450083 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:25:53 CET jreher Updated box and position via API.
07. Oct 2020 15:44:54 CEST jreher Updated APD location via API.
11. Aug 2020 17:40:34 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:40:53 CEST jreher Updated box and position via API.
27. Nov 2019 20:19:02 CET jreher Updated APD location via API.
25. Nov 2019 17:31:34 CET jreher Updated box and position via API.
22. Oct 2019 14:32:47 CEST spankonin Updated APD location via API.
15. Oct 2019 11:00:38 CEST jgrochowski Updated APD batch assignment via API.
06. Oct 2016 09:31:06 CEST markus.moritz Entered return for assembly date.
08. Sep 2016 13:36:00 CEST markus.moritz Entered shipped after irradiation date.
24. Aug 2016 14:40:44 CEST christopher.l.hahn Entered irradiation information.
24. Aug 2016 14:24:03 CEST christopher.l.hahn Entered annealing information.
11. Aug 2016 11:43:57 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:45 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:42:36 CEST Tobias Imported from Hamamatsu datasheet.