RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1310014283 - Archived data from Mon, 28. February 2022 15:57:49 CET


This is all the information about APD 1310014283. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1310014283
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F08
Break-through voltage: 436 V
Voltage for Gain 100 (T=+25°C): 407.1 V
Dark current: 8.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 323
Position in Box: 16
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 321
Position in grid: 19
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 407.5643004 V     T = -25 °C: 370.9060179 V
Voltage for Gain 150: T = +20 °C: 415.5010572 V     T = -25 °C: 378.7908647 V
Voltage for Gain 200: T = +20 °C: 419.8885557 V     T = -25 °C: 383.1166113 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.416836691 V-1     T = -25 °C: 4.510233571 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.449308206 V-1     T = -25 °C: 9.465340306 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.65858543 V-1     T = -25 °C: 14.92336635 V-1
Break-through voltage: T = +20 °C: 434.5407846 V     T = -25 °C: 398.8321456 V
   
Notes:


Version history

Time Author Change comment
28. Jul 2022 13:18:06 CEST oafedulidis Updated box and position via API.
28. Jul 2022 13:15:21 CEST oafedulidis Updated APD location via API.
08. Mar 2022 14:29:52 CET oafedulidis Updated APD characteristics via API.
08. Mar 2022 13:54:15 CET oafedulidis Updated APD batch assignment via API.
28. Feb 2022 15:57:49 CET oafedulidis Updated APD batch assignment via API.
24. Feb 2022 08:35:50 CET oafedulidis Updated APD location via API.
24. Feb 2022 08:35:29 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:58:44 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:29:45 CET jreher Updated box and position via API.
07. Oct 2020 15:45:11 CEST jreher Updated APD location via API.
11. Aug 2020 17:53:14 CEST jreher Updated APD location via API.
21. Jul 2020 16:26:38 CEST jreher Updated APD batch assignment via API.
03. Nov 2017 11:27:20 CET Tobias Resetted arrival for irradiation date because APD was returned to GSI un-irradiated.
29. Sep 2017 11:17:01 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:38 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:42:31 CEST Tobias Imported from Hamamatsu datasheet.