RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1310014282 - Archived data from Fri, 03. November 2017 11:27:20 CET


This is all the information about APD 1310014282. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1310014282
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: unknown
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B04
Break-through voltage: 439 V
Voltage for Gain 100 (T=+25°C): 410 V
Dark current: 10.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 323
Position in Box: 15
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 321
Position in grid: 18
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
28. Jul 2022 13:18:06 CEST oafedulidis Updated box and position via API.
28. Jul 2022 13:15:20 CEST oafedulidis Updated APD location via API.
08. Mar 2022 14:29:52 CET oafedulidis Updated APD characteristics via API.
08. Mar 2022 13:54:15 CET oafedulidis Updated APD batch assignment via API.
28. Feb 2022 15:57:49 CET oafedulidis Updated APD batch assignment via API.
24. Feb 2022 08:35:50 CET oafedulidis Updated APD location via API.
24. Feb 2022 08:35:29 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:58:43 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:29:45 CET jreher Updated box and position via API.
07. Oct 2020 15:45:11 CEST jreher Updated APD location via API.
11. Aug 2020 17:53:13 CEST jreher Updated APD location via API.
21. Jul 2020 16:26:38 CEST jreher Updated APD batch assignment via API.
03. Nov 2017 11:27:20 CET Tobias Resetted arrival for irradiation date because APD was returned to GSI un-irradiated.
29. Sep 2017 11:17:01 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:38 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:42:31 CEST Tobias Imported from Hamamatsu datasheet.