Show Hamamatsu Avalanche Photo Diode 1308014144 - Archived data from Tue, 11. August 2020 17:40:20 CEST
This is all the information about APD 1308014144. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1308014144 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | G04 |
| Break-through voltage: | 431.4 V |
| Voltage for Gain 100 (T=+25°C): | 403.4 V |
| Dark current: | 6.79 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 290 |
| Position in Box: | 16 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 315 |
| Position in grid: | 8 |
| Arrival for irradiation: | 02. Nov 2016 |
| Sent for analysis after irradiation: | 10. Nov 2016 |
| Return for assembly: | 09. Dec 2016 |
| Irradiation: | |
| Date: | 04. Nov 2016 |
| Dose used: | 30 Gy |
| Temperature: | 20 °C |
| Position: | 2 |
| Bias voltage: | 350 V (connected) |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 404.1372571 V T = -25 °C: 367.2665691 V |
| Voltage for Gain 150: | T = +20 °C: 412.0977129 V T = -25 °C: 375.2260126 V |
| Voltage for Gain 200: | T = +20 °C: 416.5101501 V T = -25 °C: 379.6848788 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.368859824 V-1 T = -25 °C: 4.550360649 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.178581631 V-1 T = -25 °C: 8.628859567 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 15.00953037 V-1 T = -25 °C: 13.79398061 V-1 |
| Break-through voltage: | T = +20 °C: 426.4341047 V T = -25 °C: 395.5831131 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:25:42 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:40:20 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:40:40 CEST | jreher | Updated box and position via API. |
| 27. Nov 2019 20:18:49 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:31:28 CET | jreher | Updated box and position via API. |
| 22. Oct 2019 14:31:59 CEST | spankonin | Updated APD location via API. |
| 14. Oct 2019 17:31:24 CEST | jgrochowski | Updated APD batch assignment via API. |
| 09. Dec 2016 10:27:10 CET | markus.moritz | Entered return for assembly date. |
| 23. Nov 2016 10:53:26 CET | markus.moritz | Entered shipped after irradiation date. |
| 04. Nov 2016 16:05:31 CET | markus.moritz | Entered irradiation information. |
| 02. Nov 2016 14:51:22 CET | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:28:34 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 22. Jun 2016 15:41:07 CEST | Tobias | Imported from Hamamatsu datasheet. |