| Subdetector specification: | |
|---|---|
| Serial: | 1307014066 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | In transit to Mainz | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | F08 | 
| Break-through voltage: | 436.3 V | 
| Voltage for Gain 100 (T=+25°C): | 407.9 V | 
| Dark current: | 6.93 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 45 | 
| Position in Box: | 12 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | 312 | 
| Position in grid: | 1 | 
| Arrival for irradiation: | 02. Nov 2016 | 
| Sent for analysis after irradiation: | 10. Nov 2016 | 
| Return for assembly: | 09. Dec 2016 | 
| Irradiation: | |
| Date: | 04. Nov 2016 | 
| Dose used: | 30 Gy | 
| Temperature: | 20 °C | 
| Position: | 1 | 
| Bias voltage: | 350 V (connected) | 
| Annealing: | |
| Date: | none | 
| Temperature: | none | 
| Duration: | none | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 408.4481038 V T = -25 °C: 371.3387645 V | 
| Voltage for Gain 150: | T = +20 °C: 416.3668517 V T = -25 °C: 379.2726399 V | 
| Voltage for Gain 200: | T = +20 °C: 420.7889605 V T = -25 °C: 383.6377783 V | 
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.293485596 V-1 T = -25 °C: 4.444536357 V-1 | 
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.798808898 V-1 T = -25 °C: 8.614691838 V-1 | 
| Gain/Voltage slope at M = 200: | T = +20 °C: 13.79033532 V-1 T = -25 °C: 14.53531383 V-1 | 
| Break-through voltage: | T = +20 °C: 436.481252 V T = -25 °C: 399.4417728 V | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 05. Feb 2021 10:53:57 CET | jreher | Updated box and position via API. | 
| 03. Feb 2021 18:19:45 CET | jreher | Updated box and position via API. | 
| 07. Oct 2020 15:46:04 CEST | jreher | Updated APD location via API. | 
| 11. Aug 2020 17:26:59 CEST | jreher | Updated APD characteristics via API. | 
| 27. Nov 2019 19:36:59 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:14:29 CET | jreher | Updated box and position via API. | 
| 04. Jul 2019 11:11:43 CEST | jreher | Updated APD location via API. | 
| 13. Jun 2019 10:01:32 CEST | jreher | Updated APD batch assignment via API. | 
| 09. Dec 2016 10:27:42 CET | markus.moritz | Entered return for assembly date. | 
| 23. Nov 2016 10:53:04 CET | markus.moritz | Entered shipped after irradiation date. | 
| 04. Nov 2016 16:01:16 CET | markus.moritz | Entered irradiation information. | 
| 02. Nov 2016 14:51:07 CET | markus.moritz | Entered arrival for irradiation date. | 
| 01. Aug 2016 17:28:32 CEST | Tobias | Assigned to grid via information extracted from APD DB. | 
| 22. Jun 2016 15:41:05 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					