Show Hamamatsu Avalanche Photo Diode 1305013860 - Archived data from Tue, 22. October 2019 14:31:59 CEST
					This is all the information about APD 1305013860. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1305013860 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | Bochum Box 290 | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | B04 | 
| Break-through voltage: | 444.9 V | 
| Voltage for Gain 100 (T=+25°C): | 416.4 V | 
| Dark current: | 10.5 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 290 | 
| Position in Box: | 25 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | 799 | 
| Position in grid: | 2 | 
| Arrival for irradiation: | 27. Oct 2016 | 
| Sent for analysis after irradiation: | 02. Nov 2016 | 
| Return for assembly: | 29. Nov 2016 | 
| Irradiation: | |
| Date: | 31. Oct 2016 | 
| Dose used: | 30 Gy | 
| Temperature: | 20 °C | 
| Position: | 1 | 
| Bias voltage: | 350 V (connected) | 
| Annealing: | |
| Date: | none | 
| Temperature: | none | 
| Duration: | none | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none | 
| Break-through voltage: | T = +20 °C: none T = -25 °C: none | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 05. Feb 2021 11:25:43 CET | jreher | Updated box and position via API. | 
| 11. Aug 2020 17:40:22 CEST | jreher | Updated APD characteristics via API. | 
| 21. Jul 2020 14:40:41 CEST | jreher | Updated box and position via API. | 
| 27. Nov 2019 20:18:50 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:31:28 CET | jreher | Updated box and position via API. | 
| 22. Oct 2019 14:31:59 CEST | spankonin | Updated APD location via API. | 
| 15. Oct 2019 11:02:52 CEST | jgrochowski | Updated APD batch assignment via API. | 
| 05. Apr 2018 13:58:32 CEST | jgrochowski | |
| 29. Nov 2016 11:53:51 CET | markus.moritz | Entered return for assembly date. | 
| 02. Nov 2016 14:31:59 CET | markus.moritz | Entered shipped after irradiation date. | 
| 02. Nov 2016 14:29:36 CET | markus.moritz | Entered shipped after irradiation date. | 
| 31. Oct 2016 11:49:32 CET | markus.moritz | Entered irradiation information. | 
| 27. Oct 2016 12:06:58 CEST | markus.moritz | Entered arrival for irradiation date. | 
| 01. Aug 2016 17:28:25 CEST | Tobias | Assigned to grid via information extracted from APD DB. | 
| 22. Jun 2016 15:40:59 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					