RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1302013690 - Archived data from Tue, 11. August 2020 18:03:56 CEST


This is all the information about APD 1302013690. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1302013690
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F10
Break-through voltage: 443 V
Voltage for Gain 100 (T=+25°C): 414.7 V
Dark current: 8.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 284
Position in Box: 41
EP1 batch: 202
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 293
Position in grid: 17
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 414.7317875 V     T = -25 °C: 378.229453 V
Voltage for Gain 150: T = +20 °C: 422.7056257 V     T = -25 °C: 386.1133381 V
Voltage for Gain 200: T = +20 °C: 427.1200785 V     T = -25 °C: 390.4920014 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.586767531 V-1     T = -25 °C: 4.504447143 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.103711031 V-1     T = -25 °C: 8.859549829 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.15857309 V-1     T = -25 °C: 15.50803529 V-1
Break-through voltage: T = +20 °C: 439.9986408 V     T = -25 °C: 406.2204232 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:25:00 CET jreher Updated box and position via API.
07. Oct 2020 15:44:41 CEST jreher Updated APD location via API.
11. Aug 2020 18:03:56 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:40 CEST jreher Updated APD location via API.
21. Jul 2020 14:39:30 CEST jreher Updated box and position via API.
10. Feb 2020 18:58:28 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:12 CET jreher Updated APD location via API.
27. Nov 2019 20:17:49 CET jreher Updated APD location via API.
25. Nov 2019 17:31:02 CET jreher Updated box and position via API.
22. Oct 2019 13:10:01 CEST spankonin Updated APD location via API.
09. Oct 2019 11:41:29 CEST jgrochowski Updated APD batch assignment via API.
29. Sep 2017 12:03:34 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:19 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:39:45 CEST Tobias Imported from Hamamatsu datasheet.