Show Hamamatsu Avalanche Photo Diode 1301013629 - Archived data from Fri, 26. February 2021 15:44:33 CET
					This is all the information about APD 1301013629. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1301013629 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | In transit to Bochum | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | C05 | 
| Break-through voltage: | 439 V | 
| Voltage for Gain 100 (T=+25°C): | 410.1 V | 
| Dark current: | 6.2 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 415 | 
| Position in Box: | 26 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | 291 | 
| Position in grid: | 6 | 
| Arrival for irradiation: | 29. Sep 2017 | 
| Sent for analysis after irradiation: | 27. Oct 2017 | 
| Return for assembly: | none | 
| Irradiation: | |
| Date: | 25. Oct 2017 | 
| Dose used: | 45 Gy | 
| Temperature: | 20 °C | 
| Position: | 2 | 
| Bias voltage: | 410.1 V (connected) | 
| Annealing: | |
| Date: | none | 
| Temperature: | none | 
| Duration: | none | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none | 
| Break-through voltage: | T = +20 °C: none T = -25 °C: none | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 16. Apr 2021 22:08:55 CEST | jreher | Updated APD characteristics via API. | 
| 16. Apr 2021 10:28:39 CEST | jreher | Updated APD location via API. | 
| 31. Mar 2021 14:14:47 CEST | jreher | Updated box and position via API. | 
| 26. Feb 2021 15:44:33 CET | jreher | Updated APD batch assignment via API. | 
| 03. Feb 2021 18:07:07 CET | jreher | Updated APD location via API. | 
| 27. Oct 2017 10:38:24 CEST | markus.moritz | Entered shipped after irradiation date. | 
| 26. Oct 2017 16:30:20 CEST | markus.moritz | Entered irradiation information. | 
| 29. Sep 2017 11:36:17 CEST | markus.moritz | Entered arrival for irradiation date. | 
| 01. Aug 2016 17:28:17 CEST | Tobias | Assigned to grid via information extracted from APD DB. | 
| 22. Jun 2016 15:39:44 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					