Show Hamamatsu Avalanche Photo Diode 1210013414 - Archived data from Fri, 16. April 2021 22:01:09 CEST
This is all the information about APD 1210013414. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1210013414 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | F11 |
| Break-through voltage: | 441 V |
| Voltage for Gain 100 (T=+25°C): | 413 V |
| Dark current: | 11.3 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 357 |
| Position in Box: | 33 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 283 |
| Position in grid: | 2 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 27. Oct 2017 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 25. Oct 2017 |
| Dose used: | 45 Gy |
| Temperature: | 20 °C |
| Position: | 2 |
| Bias voltage: | 413 V (connected) |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 413.2999667 V T = -25 °C: 376.3925009 V |
| Voltage for Gain 150: | T = +20 °C: 421.2208575 V T = -25 °C: 384.2324866 V |
| Voltage for Gain 200: | T = +20 °C: 425.6236808 V T = -25 °C: 388.6291745 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.447818577 V-1 T = -25 °C: 4.500939344 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.741523811 V-1 T = -25 °C: 8.754168712 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 15.10594024 V-1 T = -25 °C: 15.11507235 V-1 |
| Break-through voltage: | T = +20 °C: 439.9514135 V T = -25 °C: 404.2695778 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 21. Apr 2021 14:45:23 CEST | oafedulidis | Updated box and position via API. |
| 16. Apr 2021 22:01:09 CEST | jreher | Updated APD characteristics via API. |
| 05. Feb 2021 11:34:07 CET | jreher | Updated box and position via API. |
| 08. Oct 2020 18:15:36 CEST | jreher | Updated APD location via API. |
| 17. Aug 2020 14:32:46 CEST | vwerner | Updated APD batch assignment via API. |
| 27. Oct 2017 10:38:00 CEST | markus.moritz | Entered shipped after irradiation date. |
| 26. Oct 2017 16:27:13 CEST | markus.moritz | Entered irradiation information. |
| 29. Sep 2017 14:19:28 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:28:12 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 22. Jun 2016 15:39:39 CEST | Tobias | Imported from Hamamatsu datasheet. |