Show Hamamatsu Avalanche Photo Diode 1208013301 - Archived data from Fri, 23. September 2016 09:05:21 CEST
					This is all the information about APD 1208013301. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1208013301 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | unknown | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | C14 | 
| Break-through voltage: | 444 V | 
| Voltage for Gain 100 (T=+25°C): | 415.3 V | 
| Dark current: | 9.7 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 374 | 
| Position in Box: | 4 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | 277 | 
| Position in grid: | 18 | 
| Arrival for irradiation: | 11. Jul 2016 | 
| Sent for analysis after irradiation: | 15. Jul 2016 | 
| Return for assembly: | 19. Sep 2016 | 
| Irradiation: | |
| Date: | 13. Jul 2016 | 
| Dose used: | 30 Gy | 
| Temperature: | 25 °C | 
| Position: | 2 | 
| Bias voltage: | 320 V (connection unknown) | 
| Annealing: | |
| Date: | 13. Jul 2016 | 
| Temperature: | 80 °C | 
| Duration: | 10 h | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none | 
| Break-through voltage: | T = +20 °C: none T = -25 °C: none | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 16. Apr 2021 22:02:37 CEST | jreher | Updated APD characteristics via API. | 
| 05. Feb 2021 11:36:17 CET | jreher | Updated box and position via API. | 
| 08. Oct 2020 18:18:50 CEST | jreher | Updated APD location via API. | 
| 28. Sep 2020 14:34:49 CEST | vwerner | Updated APD batch assignment via API. | 
| 23. Sep 2016 09:05:21 CEST | markus.moritz | Entered return for assembly date. | 
| 03. Aug 2016 16:35:16 CEST | markus.moritz | Entered irradiation information. | 
| 03. Aug 2016 16:18:05 CEST | markus.moritz | Entered shipped after irradiation date. | 
| 02. Aug 2016 14:59:16 CEST | christopher.l.hahn | Entered annealing information. | 
| 02. Aug 2016 10:45:08 CEST | markus.moritz | Entered arrival for irradiation date. | 
| 01. Aug 2016 17:28:09 CEST | Tobias | Assigned to grid via information extracted from APD DB. | 
| 22. Jun 2016 15:39:36 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					