Show Hamamatsu Avalanche Photo Diode 1204012960 - Archived data from Tue, 11. August 2020 18:10:12 CEST
This is all the information about APD 1204012960. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1204012960 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | E04 |
| Break-through voltage: | 434 V |
| Voltage for Gain 100 (T=+25°C): | 406 V |
| Dark current: | 13.2 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 275 |
| Position in Box: | 46 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 262 |
| Position in grid: | 1 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | none |
| Dose used: | none |
| Temperature: | none |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 406.8730898 V T = -25 °C: 370.0442376 V |
| Voltage for Gain 150: | T = +20 °C: 414.801131 V T = -25 °C: 377.899888 V |
| Voltage for Gain 200: | T = +20 °C: 419.185997 V T = -25 °C: 382.2582683 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.574851183 V-1 T = -25 °C: 4.552553785 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.078039243 V-1 T = -25 °C: 9.040932299 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.18237296 V-1 T = -25 °C: 14.09198416 V-1 |
| Break-through voltage: | T = +20 °C: 434.3885328 V T = -25 °C: 397.7933542 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:23:50 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 18:10:12 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:37:27 CEST | jreher | Updated APD location via API. |
| 21. Jul 2020 14:37:18 CEST | jreher | Updated box and position via API. |
| 29. Jun 2020 16:14:06 CEST | jreher | Updated APD batch assignment via API. |
| 29. Sep 2017 11:22:27 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:27:58 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 22. Jun 2016 15:37:53 CEST | Tobias | Imported from Hamamatsu datasheet. |