Show Hamamatsu Avalanche Photo Diode 1201012775 - Archived data from Wed, 07. October 2020 15:45:08 CEST
This is all the information about APD 1201012775. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1201012775 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | In transit to Mainz |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | C08 |
| Break-through voltage: | 442 V |
| Voltage for Gain 100 (T=+25°C): | 413.9 V |
| Dark current: | 7.1 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 304 |
| Position in Box: | 29 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 253 |
| Position in grid: | 18 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 27. Oct 2017 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 25. Oct 2017 |
| Dose used: | 45 Gy |
| Temperature: | 20 °C |
| Position: | 1 |
| Bias voltage: | 413.9 V (connected) |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 414.6052649 V T = -25 °C: 378.0344427 V |
| Voltage for Gain 150: | T = +20 °C: 422.6657182 V T = -25 °C: 385.9453798 V |
| Voltage for Gain 200: | T = +20 °C: 427.1023309 V T = -25 °C: 390.3399481 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.311328861 V-1 T = -25 °C: 4.572673911 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.205620743 V-1 T = -25 °C: 9.080686118 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.15472032 V-1 T = -25 °C: 13.97470169 V-1 |
| Break-through voltage: | T = +20 °C: 440.0111755 V T = -25 °C: 405.3472905 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:27:32 CET | jreher | Updated box and position via API. |
| 07. Oct 2020 15:45:08 CEST | jreher | Updated APD location via API. |
| 11. Aug 2020 17:57:52 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:43:56 CEST | jreher | Updated APD location via API. |
| 21. Jul 2020 14:43:46 CEST | jreher | Updated box and position via API. |
| 19. Dec 2019 16:20:00 CET | spankonin | Updated APD batch assignment via API. |
| 19. Dec 2019 15:18:22 CET | jreher | Updated box and position via API. |
| 27. Oct 2017 10:38:42 CEST | markus.moritz | Entered shipped after irradiation date. |
| 26. Oct 2017 16:29:49 CEST | markus.moritz | Entered irradiation information. |
| 29. Sep 2017 11:53:38 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:27:52 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 22. Jun 2016 15:37:48 CEST | Tobias | Imported from Hamamatsu datasheet. |