Show Hamamatsu Avalanche Photo Diode 0910009737 - Archived data from Thu, 13. June 2019 10:01:13 CEST
This is all the information about APD 0910009737. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 0910009737 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | unknown |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | C06 |
| Break-through voltage: | 415 V |
| Voltage for Gain 100 (T=+25°C): | 386.1 V |
| Dark current: | 4 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 44 |
| Position in Box: | 33 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 207 |
| Position in grid: | 3 |
| Arrival for irradiation: | 15. May 2016 |
| Sent for analysis after irradiation: | 23. Jun 2016 |
| Return for assembly: | 20. Dec 2016 |
| Irradiation: | |
| Date: | 20. May 2016 |
| Dose used: | 57 Gy |
| Temperature: | -25 °C |
| Position: | 1 |
| Bias voltage: | 320 V (connection unknown) |
| Annealing: | |
| Date: | 20. May 2016 |
| Temperature: | 80 °C |
| Duration: | 8 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: | has been irradiated and annealed again (sent to Gießen on 24_07_2018, irradiated on 16_08_2018 with 30Gy at 20°C, annealed on 17_08_2018 at 80°C for 48h, sent to analysis on 21_08_2018) |
Version history
| Time | Author | Change comment |
|---|---|---|
| 22. Feb 2021 11:10:50 CET | jreher | Updated box and position via API. |
| 05. Feb 2021 10:53:52 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:19:40 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:26:53 CEST | jreher | Updated APD characteristics via API. |
| 04. Aug 2020 15:48:19 CEST | jreher | Updated box and position via API. |
| 27. Nov 2019 19:36:50 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:14:25 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:11:36 CEST | jreher | Updated APD location via API. |
| 13. Jun 2019 10:01:13 CEST | jreher | Updated APD batch assignment via API. |
| 21. Aug 2018 11:44:28 CEST | markus.moritz | |
| 20. Dec 2016 10:37:11 CET | markus.moritz | Entered return for assembly date. |
| 03. Aug 2016 16:10:39 CEST | markus.moritz | Entered shipped after irradiation date. |
| 03. Aug 2016 16:10:26 CEST | markus.moritz | Entered arrival for irradiation date. |
| 02. Aug 2016 16:26:46 CEST | markus.moritz | Entered irradiation information. |
| 02. Aug 2016 15:17:47 CEST | christopher.l.hahn | Entered annealing information. |
| 01. Aug 2016 17:52:06 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 22. Jun 2016 15:34:20 CEST | Tobias | Imported from Hamamatsu datasheet. |