RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0910009734 - Archived data from Fri, 05. February 2021 10:53:53 CET


This is all the information about APD 0910009734. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0910009734
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F06
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 387.2 V
Dark current: 3.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 44
Position in Box: 44
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 207
Position in grid: 16
Arrival for irradiation: 15. May 2016
Sent for analysis after irradiation: 23. Jun 2016
Return for assembly: 20. Dec 2016
   
Irradiation:  
Date: 20. May 2016
Dose used: 57 Gy
Temperature: -25 °C
Position: 1
Bias voltage: 320 V     (connection unknown)
   
Annealing:  
Date: 20. May 2016
Temperature: 80 °C
Duration: 8 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.7147879 V     T = -25 °C: 350.4348164 V
Voltage for Gain 150: T = +20 °C: 394.6641211 V     T = -25 °C: 357.9825185 V
Voltage for Gain 200: T = +20 °C: 399.0476457 V     T = -25 °C: 362.2099941 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.621439111 V-1     T = -25 °C: 4.573638359 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.564870353 V-1     T = -25 °C: 9.378912041 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.36341066 V-1     T = -25 °C: 14.47827164 V-1
Break-through voltage: T = +20 °C: 414.3750259 V     T = -25 °C: 377.2215332 V
   
Notes:


Version history

Time Author Change comment
22. Feb 2021 11:10:51 CET jreher Updated box and position via API.
05. Feb 2021 10:53:53 CET jreher Updated box and position via API.
03. Feb 2021 18:19:41 CET jreher Updated box and position via API.
11. Aug 2020 17:26:55 CEST jreher Updated APD characteristics via API.
04. Aug 2020 15:48:20 CEST jreher Updated box and position via API.
27. Nov 2019 19:36:50 CET jreher Updated APD location via API.
25. Nov 2019 17:14:27 CET jreher Updated box and position via API.
04. Jul 2019 11:11:37 CEST jreher Updated APD location via API.
13. Jun 2019 10:01:31 CEST jreher Updated APD batch assignment via API.
20. Dec 2016 10:37:11 CET markus.moritz Entered return for assembly date.
03. Aug 2016 16:10:39 CEST markus.moritz Entered shipped after irradiation date.
03. Aug 2016 16:10:26 CEST markus.moritz Entered arrival for irradiation date.
02. Aug 2016 16:26:46 CEST markus.moritz Entered irradiation information.
02. Aug 2016 15:17:47 CEST christopher.l.hahn Entered annealing information.
01. Aug 2016 17:52:07 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:34:20 CEST Tobias Imported from Hamamatsu datasheet.