RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0906009426 - Archived data from Fri, 16. April 2021 22:00:53 CEST


This is all the information about APD 0906009426. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0906009426
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C10
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.7 V
Dark current: 5.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 355
Position in Box: 8
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.1527091 V     T = -25 °C: 348.5065915 V
Voltage for Gain 150: T = +20 °C: 392.0610631 V     T = -25 °C: 355.9537554 V
Voltage for Gain 200: T = +20 °C: 396.453664 V     T = -25 °C: 360.1486811 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.524508158 V-1     T = -25 °C: 4.710678339 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.870118736 V-1     T = -25 °C: 9.372422617 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.50264126 V-1     T = -25 °C: 14.79181571 V-1
Break-through voltage: T = +20 °C: 411.3357511 V     T = -25 °C: 375.2659623 V
   
Notes:


Version history

Time Author Change comment
21. Apr 2021 14:46:42 CEST oafedulidis Updated box and position via API.
16. Apr 2021 22:00:53 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:33:49 CET jreher Updated box and position via API.
08. Oct 2020 18:15:10 CEST jreher Updated APD location via API.
17. Aug 2020 14:25:44 CEST vwerner Updated APD batch assignment via API.
22. Jun 2016 15:31:47 CEST Tobias Imported from Hamamatsu datasheet.