RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0904009248 - Archived data from Wed, 16. June 2021 15:59:47 CEST


This is all the information about APD 0904009248. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0904009248
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E12
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.4 V
Dark current: 6.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 294
Position in Box: 41
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 186
Position in grid: 18
Arrival for irradiation: 30. Oct 2017
Sent for analysis after irradiation: 17. Nov 2017
Return for assembly: none
   
Irradiation:  
Date: 16. Nov 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 1
Bias voltage: 386.4 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.198662 V     T = -25 °C: 350.2146976 V
Voltage for Gain 150: T = +20 °C: 394.1576778 V     T = -25 °C: 357.7334735 V
Voltage for Gain 200: T = +20 °C: 398.5817938 V     T = -25 °C: 362.0298295 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.467876271 V-1     T = -25 °C: 3.991993006 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.682538429 V-1     T = -25 °C: 9.249716468 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.05681064 V-1     T = -25 °C: 14.36104469 V-1
Break-through voltage: T = +20 °C: 414.2764688 V     T = -25 °C: 377.6767422 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 10:34:30 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:29 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:59:47 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:27 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:26:15 CET jreher Updated box and position via API.
11. Aug 2020 17:56:15 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:41:29 CEST jreher Updated APD location via API.
21. Jul 2020 14:41:20 CEST jreher Updated box and position via API.
19. Dec 2019 15:44:45 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:17:06 CET jreher Updated box and position via API.
17. Nov 2017 09:39:23 CET markus.moritz Entered shipped after irradiation date.
17. Nov 2017 09:37:18 CET markus.moritz Entered irradiation information.
09. Nov 2017 15:11:11 CET markus.moritz Entered arrival for irradiation date.
02. Nov 2017 15:16:54 CET Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:31:43 CEST Tobias Imported from Hamamatsu datasheet.