RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0904009235 - Archived data from Fri, 05. February 2021 11:26:13 CET


This is all the information about APD 0904009235. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0904009235
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E14
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.6 V
Dark current: 6.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 294
Position in Box: 31
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 186
Position in grid: 15
Arrival for irradiation: 30. Oct 2017
Sent for analysis after irradiation: 17. Nov 2017
Return for assembly: none
   
Irradiation:  
Date: 16. Nov 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 1
Bias voltage: 386.6 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.507279 V     T = -25 °C: 350.5418111 V
Voltage for Gain 150: T = +20 °C: 394.4664418 V     T = -25 °C: 358.0249039 V
Voltage for Gain 200: T = +20 °C: 398.8713609 V     T = -25 °C: 362.3408747 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.395016888 V-1     T = -25 °C: 3.918361491 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.490846646 V-1     T = -25 °C: 9.055548471 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.72960231 V-1     T = -25 °C: 13.95777662 V-1
Break-through voltage: T = +20 °C: 414.416544 V     T = -25 °C: 378.0103501 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:31:15 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 11:14:27 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:26:13 CET jreher Updated box and position via API.
11. Aug 2020 17:56:13 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:41:28 CEST jreher Updated APD location via API.
21. Jul 2020 14:41:19 CEST jreher Updated box and position via API.
19. Dec 2019 15:44:45 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:17:05 CET jreher Updated box and position via API.
17. Nov 2017 09:39:23 CET markus.moritz Entered shipped after irradiation date.
17. Nov 2017 09:37:17 CET markus.moritz Entered irradiation information.
09. Nov 2017 15:11:11 CET markus.moritz Entered arrival for irradiation date.
02. Nov 2017 15:16:54 CET Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:31:43 CEST Tobias Imported from Hamamatsu datasheet.