Show Hamamatsu Avalanche Photo Diode 0902009175 - Archived data from Thu, 23. June 2016 10:03:46 CEST
This is all the information about APD 0902009175. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 0902009175 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | unknown |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | E12 |
| Break-through voltage: | 408 V |
| Voltage for Gain 100 (T=+25°C): | 379.6 V |
| Dark current: | 8.4 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 295 |
| Position in Box: | 2 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | none |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | none |
| Dose used: | none |
| Temperature: | none |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: | Wrong wafer number in serial number, correct wafer number is 3. |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:26:18 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:56:17 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:41:32 CEST | jreher | Updated box and position via API. |
| 19. Dec 2019 15:44:46 CET | spankonin | Updated APD batch assignment via API. |
| 19. Dec 2019 15:17:17 CET | jreher | Updated APD location via API. |
| 19. Dec 2019 15:17:10 CET | jreher | Updated box and position via API. |
| 17. Nov 2017 09:39:16 CET | markus.moritz | Entered shipped after irradiation date. |
| 17. Nov 2017 09:38:13 CET | markus.moritz | Entered irradiation information. |
| 09. Nov 2017 15:11:05 CET | markus.moritz | Entered arrival for irradiation date. |
| 02. Nov 2017 15:16:53 CET | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:03:46 CEST | Tobias | Added note about wrong wafer number. |
| 22. Jun 2016 15:31:42 CEST | Tobias | Imported from Hamamatsu datasheet. |