RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0902009156 - Archived data from Mon, 17. August 2020 16:01:00 CEST


This is all the information about APD 0902009156. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0902009156
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E09
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.4 V
Dark current: 6.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 53
Position in Box: 28
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 04. Jun 2019
Return for assembly: none
   
Irradiation:  
Date: 29. May 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 29. May 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.7424602 V     T = -25 °C: 350.4084773 V
Voltage for Gain 150: T = +20 °C: 394.6386801 V     T = -25 °C: 357.8921212 V
Voltage for Gain 200: T = +20 °C: 399.0553719 V     T = -25 °C: 362.0961675 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.617843007 V-1     T = -25 °C: 4.59713277 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.043583385 V-1     T = -25 °C: 9.404760028 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.15455309 V-1     T = -25 °C: 14.26444374 V-1
Break-through voltage: T = +20 °C: 414.7755824 V     T = -25 °C: 377.8051421 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:55:11 CET jreher Updated box and position via API.
03. Feb 2021 18:20:46 CET jreher Updated box and position via API.
08. Dec 2020 17:07:00 CET jreher Assigned to capsule by script
17. Aug 2020 16:01:00 CEST vwerner Updated box and position via API.
11. Aug 2020 17:27:40 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:38:05 CET jreher Updated APD location via API.
25. Nov 2019 17:15:06 CET jreher Updated box and position via API.
04. Jul 2019 11:12:27 CEST jreher Updated APD location via API.
18. Jun 2019 13:18:50 CEST jgrochowski Updated APD batch assignment via API.
04. Jun 2019 11:04:28 CEST markus.moritz
22. Jun 2016 15:31:41 CEST Tobias Imported from Hamamatsu datasheet.