RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0901009039 - Archived data from Fri, 29. January 2021 10:23:34 CET


This is all the information about APD 0901009039. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0901009039
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2309024928/0901009039
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: F05
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 385 V
Dark current: 6.4 nA
   
Screening Logistics:  
Available: No
Storage Box: 57
Position in Box: 30
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 04. Jun 2019
Return for assembly: none
   
Irradiation:  
Date: 29. May 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 29. May 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.8965633 V     T = -25 °C: 349.4318967 V
Voltage for Gain 150: T = +20 °C: 392.834031 V     T = -25 °C: 356.8065106 V
Voltage for Gain 200: T = +20 °C: 397.2487657 V     T = -25 °C: 361.0394963 V
Gain/Voltage slope at M = 100: T = +20 °C: 5.069934062 V-1     T = -25 °C: 4.711626583 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.027769162 V-1     T = -25 °C: 8.723719043 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.05042484 V-1     T = -25 °C: 14.05850811 V-1
Break-through voltage: T = +20 °C: 412.4878214 V     T = -25 °C: 376.3522135 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:55:44 CET jreher Updated box and position via API.
03. Feb 2021 18:21:17 CET jreher Updated box and position via API.
29. Jan 2021 10:23:34 CET jreher Assigned to capsule by script
06. Oct 2020 16:52:45 CEST jreher Updated box and position via API.
11. Aug 2020 17:28:20 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:38:49 CET jreher Updated APD location via API.
25. Nov 2019 17:15:25 CET jreher Updated box and position via API.
04. Jul 2019 11:12:59 CEST jreher Updated APD location via API.
03. Jul 2019 18:43:28 CEST jreher Updated APD batch assignment via API.
24. Jun 2019 13:02:36 CEST jgrochowski Updated APD batch assignment via API.
18. Jun 2019 14:19:32 CEST jgrochowski Updated APD batch assignment via API.
04. Jun 2019 13:31:48 CEST markus.moritz
22. Jun 2016 15:31:38 CEST Tobias Imported from Hamamatsu datasheet.