RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0818008573 - Archived data from Tue, 11. August 2020 17:40:26 CEST


This is all the information about APD 0818008573. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0818008573
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G03
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 384.6 V
Dark current: 2.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 290
Position in Box: 43
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 67
Position in grid: 5
Arrival for irradiation: 15. May 2016
Sent for analysis after irradiation: 23. Jun 2016
Return for assembly: 29. Nov 2016
   
Irradiation:  
Date: 20. May 2016
Dose used: 250 Gy
Temperature: -25 °C
Position: 1
Bias voltage: 320 V     (connection unknown)
   
Annealing:  
Date: 20. May 2016
Temperature: 80 °C
Duration: 8 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.1052027 V     T = -25 °C: 349.3660569 V
Voltage for Gain 150: T = +20 °C: 393.1485057 V     T = -25 °C: 356.9206214 V
Voltage for Gain 200: T = +20 °C: 397.6229268 V     T = -25 °C: 361.1891765 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.445556302 V-1     T = -25 °C: 4.659527298 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.572362307 V-1     T = -25 °C: 9.224745946 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.63191275 V-1     T = -25 °C: 14.24634763 V-1
Break-through voltage: T = +20 °C: 409.4728945 V     T = -25 °C: 376.452302 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:25:45 CET jreher Updated box and position via API.
11. Aug 2020 17:40:26 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:40:42 CEST jreher Updated box and position via API.
27. Nov 2019 20:18:51 CET jreher Updated APD location via API.
25. Nov 2019 17:31:30 CET jreher Updated box and position via API.
22. Oct 2019 14:32:01 CEST spankonin Updated APD location via API.
15. Oct 2019 11:02:54 CEST jgrochowski Updated APD batch assignment via API.
29. Nov 2016 11:51:58 CET markus.moritz Entered return for assembly date.
04. Aug 2016 12:45:56 CEST markus.moritz Entered arrival for irradiation date.
03. Aug 2016 16:03:20 CEST markus.moritz Entered shipped after irradiation date.
03. Aug 2016 16:03:08 CEST markus.moritz Entered arrival for irradiation date.
02. Aug 2016 15:18:06 CEST christopher.l.hahn Entered annealing information.
02. Aug 2016 14:00:56 CEST markus.moritz Entered irradiation information.
01. Aug 2016 17:27:50 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:27:54 CEST Tobias Imported from Hamamatsu datasheet.