Show Hamamatsu Avalanche Photo Diode 0817008516 - Archived data from Tue, 16. February 2021 12:27:18 CET
This is all the information about APD 0817008516. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 0817008516 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | F10 |
| Break-through voltage: | 408 V |
| Voltage for Gain 100 (T=+25°C): | 381 V |
| Dark current: | 4.7 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 355 |
| Position in Box: | 50 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 79 |
| Position in grid: | 19 |
| Arrival for irradiation: | 03. Aug 2017 |
| Sent for analysis after irradiation: | 22. Aug 2017 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 11. Aug 2017 |
| Dose used: | 46 Gy |
| Temperature: | 20 °C |
| Position: | 4 |
| Bias voltage: | 381 V (connected) |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 17. Jun 2021 19:22:29 CEST | oafedulidis | Assigned to capsule by script |
| 16. Apr 2021 22:00:56 CEST | jreher | Updated APD characteristics via API. |
| 16. Feb 2021 12:27:18 CET | jreher | Updated box and position via API. |
| 05. Feb 2021 11:33:53 CET | jreher | Updated box and position via API. |
| 08. Oct 2020 18:15:15 CEST | jreher | Updated APD location via API. |
| 17. Aug 2020 14:26:34 CEST | vwerner | Updated APD batch assignment via API. |
| 23. Aug 2017 15:52:59 CEST | markus.moritz | Entered shipped after irradiation date. |
| 11. Aug 2017 14:12:08 CEST | hans-georg.zaunick | Entered irradiation information. |
| 07. Aug 2017 16:56:15 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
| 07. Aug 2017 16:50:38 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
| 04. Aug 2017 03:15:16 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 22. Jun 2016 15:27:53 CEST | Tobias | Imported from Hamamatsu datasheet. |