Show Hamamatsu Avalanche Photo Diode 0817008483 - Archived data from Tue, 11. August 2020 17:57:07 CEST
This is all the information about APD 0817008483. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 0817008483 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | G05 |
| Break-through voltage: | 408 V |
| Voltage for Gain 100 (T=+25°C): | 379.9 V |
| Dark current: | 3 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 300 |
| Position in Box: | 9 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 78 |
| Position in grid: | 5 |
| Arrival for irradiation: | 03. Aug 2017 |
| Sent for analysis after irradiation: | 23. Aug 2017 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 11. Aug 2017 |
| Dose used: | 46 Gy |
| Temperature: | 20 °C |
| Position: | 3 |
| Bias voltage: | 379.9 V (connected) |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 380.1019315 V T = -25 °C: 344.5246967 V |
| Voltage for Gain 150: | T = +20 °C: 387.9975298 V T = -25 °C: 351.9632644 V |
| Voltage for Gain 200: | T = +20 °C: 392.3994768 V T = -25 °C: 356.1605125 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.552961968 V-1 T = -25 °C: 4.699256121 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.92693797 V-1 T = -25 °C: 9.454928863 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 13.79976778 V-1 T = -25 °C: 14.78602312 V-1 |
| Break-through voltage: | T = +20 °C: 406.8960789 V T = -25 °C: 371.8413529 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:26:59 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:57:07 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:42:54 CEST | jreher | Updated APD location via API. |
| 21. Jul 2020 14:42:44 CEST | jreher | Updated box and position via API. |
| 19. Dec 2019 15:52:01 CET | spankonin | Updated APD batch assignment via API. |
| 19. Dec 2019 15:17:50 CET | jreher | Updated box and position via API. |
| 23. Aug 2017 15:53:23 CEST | markus.moritz | Entered shipped after irradiation date. |
| 11. Aug 2017 14:11:33 CEST | hans-georg.zaunick | Entered irradiation information. |
| 07. Aug 2017 16:55:57 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
| 07. Aug 2017 16:50:11 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
| 04. Aug 2017 03:15:14 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 22. Jun 2016 15:27:52 CEST | Tobias | Imported from Hamamatsu datasheet. |