Show Hamamatsu Avalanche Photo Diode 0814008288 - Archived data from Tue, 11. August 2020 17:56:55 CEST
This is all the information about APD 0814008288. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0814008288 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C13 |
Break-through voltage: | 426 V |
Voltage for Gain 100 (T=+25°C): | 397.4 V |
Dark current: | 3.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 298 |
Position in Box: | 48 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 69 |
Position in grid: | 1 |
Arrival for irradiation: | 03. Aug 2017 |
Sent for analysis after irradiation: | 10. Aug 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Aug 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 3 |
Bias voltage: | 397.4 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 397.9603056 V T = -25 °C: 361.1988741 V |
Voltage for Gain 150: | T = +20 °C: 405.8224186 V T = -25 °C: 368.917947 V |
Voltage for Gain 200: | T = +20 °C: 410.1782094 V T = -25 °C: 373.2359711 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.61124717 V-1 T = -25 °C: 4.641344049 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.159505739 V-1 T = -25 °C: 9.164775241 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.31871178 V-1 T = -25 °C: 14.34028093 V-1 |
Break-through voltage: | T = +20 °C: 425.8667628 V T = -25 °C: 389.1949107 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:26:47 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:56:55 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:42:28 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:42:19 CEST | jreher | Updated box and position via API. |
19. Dec 2019 15:50:06 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:17:38 CET | jreher | Updated box and position via API. |
10. Aug 2017 15:16:13 CEST | hans-georg.zaunick | Entered shipped after irradiation date. |
09. Aug 2017 14:26:50 CEST | hans-georg.zaunick | Entered irradiation information. |
07. Aug 2017 16:54:47 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
07. Aug 2017 16:47:55 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
04. Aug 2017 03:15:09 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:27:48 CEST | Tobias | Imported from Hamamatsu datasheet. |