Show Hamamatsu Avalanche Photo Diode 0814008232 - Archived data from Tue, 11. August 2020 17:36:20 CEST
This is all the information about APD 0814008232. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 0814008232 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | H07 |
| Break-through voltage: | 422 V |
| Voltage for Gain 100 (T=+25°C): | 393.6 V |
| Dark current: | 3.7 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 200 |
| Position in Box: | 3 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 18. Apr 2019 |
| Sent for analysis after irradiation: | 29. Jul 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 25. Jul 2019 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 27. Jul 2019 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 394.7227319 V T = -25 °C: 359.1589796 V |
| Voltage for Gain 150: | T = +20 °C: 402.5898594 V T = -25 °C: 366.8099894 V |
| Voltage for Gain 200: | T = +20 °C: 406.9565632 V T = -25 °C: 371.0293162 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.633742007 V-1 T = -25 °C: 4.634375268 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.117391643 V-1 T = -25 °C: 7.753618103 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.11162481 V-1 T = -25 °C: 16.22686453 V-1 |
| Break-through voltage: | T = +20 °C: 421.5380622 V T = -25 °C: 385.3593292 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 21. Apr 2021 14:48:49 CEST | oafedulidis | Updated box and position via API. |
| 05. Feb 2021 11:14:10 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:36:20 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 20:04:29 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:26:37 CET | jreher | Updated box and position via API. |
| 13. Aug 2019 14:45:48 CEST | spankonin | Updated APD batch assignment via API. |
| 07. Aug 2019 16:16:29 CEST | markus.moritz | |
| 22. Jun 2016 15:26:20 CEST | Tobias | Imported from Hamamatsu datasheet. |