RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0614005125 - Archived data from Tue, 11. August 2020 17:48:36 CEST


This is all the information about APD 0614005125. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0614005125
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H07
Break-through voltage: 443 V
Voltage for Gain 100 (T=+25°C): 415.4 V
Dark current: 15.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 249
Position in Box: 5
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 416.405991 V     T = -25 °C: 379.3334093 V
Voltage for Gain 150: T = +20 °C: 424.2455056 V     T = -25 °C: 387.1615408 V
Voltage for Gain 200: T = +20 °C: 428.5908179 V     T = -25 °C: 391.5097557 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.466748108 V-1     T = -25 °C: 4.509643308 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.81360877 V-1     T = -25 °C: 8.908697734 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.43879782 V-1     T = -25 °C: 15.62785174 V-1
Break-through voltage: T = +20 °C: 439.9828056 V     T = -25 °C: 406.2165349 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:20:19 CET jreher Updated box and position via API.
11. Aug 2020 17:48:36 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:32:18 CEST jreher Updated box and position via API.
27. Nov 2019 20:13:01 CET jreher Updated APD location via API.
25. Nov 2019 17:29:57 CET jreher Updated box and position via API.
21. Nov 2019 16:54:40 CET spankonin Updated APD location via API.
21. Nov 2019 16:41:38 CET spankonin Updated APD batch assignment via API.
18. Jun 2019 10:18:29 CEST Tobias Imported from Hamamatsu datasheet.