Show Hamamatsu Avalanche Photo Diode 0613005026 - Archived data from Tue, 11. August 2020 17:27:21 CEST
					This is all the information about APD 0613005026. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 0613005026 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | Bochum | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | H08 | 
| Break-through voltage: | 450 V | 
| Voltage for Gain 100 (T=+25°C): | 422.5 V | 
| Dark current: | 14.8 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 46 | 
| Position in Box: | 31 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | none | 
| Position in grid: | none | 
| Arrival for irradiation: | none | 
| Sent for analysis after irradiation: | none | 
| Return for assembly: | none | 
| Irradiation: | |
| Date: | none | 
| Dose used: | none | 
| Temperature: | none | 
| Position: | none | 
| Bias voltage: | none | 
| Annealing: | |
| Date: | none | 
| Temperature: | none | 
| Duration: | none | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 427.6893617 V T = -25 °C: 390.8623343 V | 
| Voltage for Gain 150: | T = +20 °C: 435.5996478 V T = -25 °C: 398.7125487 V | 
| Voltage for Gain 200: | T = +20 °C: 439.3867425 V T = -25 °C: 402.9835396 V | 
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.221765395 V-1 T = -25 °C: 4.966651811 V-1 | 
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.474776974 V-1 T = -25 °C: 9.947895562 V-1 | 
| Gain/Voltage slope at M = 200: | T = +20 °C: 12.68603882 V-1 T = -25 °C: 13.67003281 V-1 | 
| Break-through voltage: | T = +20 °C: 440.0014986 V T = -25 °C: 415.0044717 V | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 05. Feb 2021 10:54:10 CET | jreher | Updated box and position via API. | 
| 03. Feb 2021 18:19:54 CET | jreher | Updated box and position via API. | 
| 07. Oct 2020 15:46:09 CEST | jreher | Updated APD location via API. | 
| 11. Aug 2020 17:27:21 CEST | jreher | Updated APD characteristics via API. | 
| 27. Nov 2019 19:37:10 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:14:34 CET | jreher | Updated box and position via API. | 
| 04. Jul 2019 11:11:53 CEST | jreher | Updated APD location via API. | 
| 18. Jun 2019 13:30:08 CEST | jgrochowski | Updated APD batch assignment via API. | 
| 18. Jun 2019 10:18:21 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					