RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3315036392 - Archived data from Tue, 11. August 2020 18:02:51 CEST


This is all the information about APD 3315036392. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3315036392
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D11
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 383.3 V
Dark current: 36.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 155
Position in Box: 44
EP1 batch: 184
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.7611327 V     T = -25 °C: 348.8964688 V
Voltage for Gain 150: T = +20 °C: 391.4300525 V     T = -25 °C: 356.0593724 V
Voltage for Gain 200: T = +20 °C: 395.6947194 V     T = -25 °C: 360.0685151 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.495623667 V-1     T = -25 °C: 5.15765049 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.878186963 V-1     T = -25 °C: 9.84936346 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.8043853 V-1     T = -25 °C: 15.99971555 V-1
Break-through voltage: T = +20 °C: 409.6034608 V     T = -25 °C: 373.7125855 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:08:17 CET jreher Updated box and position via API.
11. Aug 2020 18:02:51 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:52:25 CEST jreher Updated APD location via API.
03. Feb 2020 14:21:48 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:49:32 CET jreher Updated APD location via API.
27. Nov 2019 19:56:17 CET jreher Updated APD location via API.
25. Nov 2019 17:23:11 CET jreher Updated box and position via API.
01. Oct 2019 11:33:07 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:56:51 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:28 CET Tobias Corrected dark current unit.