RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3313036214 - Archived data from Tue, 11. August 2020 18:02:24 CEST


This is all the information about APD 3313036214. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3313036214
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E07
Break-through voltage: 403 V
Voltage for Gain 100 (T=+25°C): 375.8 V
Dark current: 17.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 153
Position in Box: 7
EP1 batch: 180
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 375.3080105 V     T = -25 °C: 341.7794996 V
Voltage for Gain 150: T = +20 °C: 382.9393391 V     T = -25 °C: 348.8281568 V
Voltage for Gain 200: T = +20 °C: 387.2170496 V     T = -25 °C: 352.765068 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.661166853 V-1     T = -25 °C: 5.106130365 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.245345967 V-1     T = -25 °C: 9.646443262 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.39732026 V-1     T = -25 °C: 16.37138606 V-1
Break-through voltage: T = +20 °C: 402.7585444 V     T = -25 °C: 367.204454 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:07:57 CET jreher Updated box and position via API.
11. Aug 2020 18:02:24 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:52:13 CEST jreher Updated APD location via API.
03. Feb 2020 14:23:45 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:49:22 CET jreher Updated APD location via API.
27. Nov 2019 19:55:52 CET jreher Updated APD location via API.
25. Nov 2019 17:22:57 CET jreher Updated box and position via API.
01. Oct 2019 11:31:24 CEST spankonin Updated APD batch assignment via API.
01. Oct 2019 11:30:25 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:56:32 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:23 CET Tobias Corrected dark current unit.
19. Sep 2018 14:05:32 CEST Tobias Imported from Hamamatsu datasheet.