Show Hamamatsu Avalanche Photo Diode 3312036111 - Archived data from Fri, 05. July 2019 13:56:18 CEST
This is all the information about APD 3312036111. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 3312036111 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum Box 151 |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | C06 |
| Break-through voltage: | 410 V |
| Voltage for Gain 100 (T=+25°C): | 382.1 V |
| Dark current: | 18.1 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 151 |
| Position in Box: | 37 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | none |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | none |
| Dose used: | none |
| Temperature: | none |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:07:45 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 18:02:10 CEST | jreher | Updated APD characteristics via API. |
| 11. Aug 2020 17:52:06 CEST | jreher | Updated APD location via API. |
| 03. Feb 2020 14:24:22 CET | spankonin | Updated APD batch assignment via API. |
| 29. Nov 2019 11:49:16 CET | jreher | Updated APD location via API. |
| 27. Nov 2019 19:55:32 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:22:50 CET | jreher | Updated box and position via API. |
| 26. Sep 2019 15:32:33 CEST | jgrochowski | Updated APD batch assignment via API. |
| 05. Jul 2019 13:56:18 CEST | jreher | Updated APD location via API. |
| 03. Jan 2019 00:15:20 CET | Tobias | Corrected dark current unit. |
| 19. Sep 2018 14:05:30 CEST | Tobias | Imported from Hamamatsu datasheet. |